Features:
- Reduced extractables. Lower levels of extractable fluoride ions reduce silicone wafer corrosion.
- Superior chemical and heat resistance.
- Wide temperature range.
- Durable, kink resistant, with no external wire reinforcement to potentially fray.
- Easy-to-clean non-stick smooth tube for assured sterility.
- Can be cleaned with steam, caustic, solvent or other cleaning agents.
|
Temperature Rating
177°C (350°F) to -40°C (-40°F)
Common Uses:
- HCL
- HF
- H2SO4
- Sodium Hydroxide
- Peroxide
Approvals:
Colors:
White with gray layline.
Construction:
- Inner Tube: Unpigmented Chemfluor® PFA.
- Cover: EPDM Rubber
- Reinforcement: Multiple polyester plycord and EPDM Rubber. Double Helix, High Tensile Strength Steel Wire.
Fittings:
- Over 40 styles of stocked PermaSeal® crimp-style fittings.
- A wide range of materials available.
- Standard: 316L Stainless Steel (Wetted Surfaces)
- Flare-Thru Fitting Technology available including 150# swivel style flanges, Female cam and groove (swivel style, 316 Stainless Steel body. Sanitary clamp style not available (see W.S.I.B.)
WTLCTPFA Hose Specifications
Part Number |
Hose Size ID |
Size Nominal OD |
Recom.'d Working Pressure (P.S.I.) |
Vacuum Rating @70°F |
Min. Burst Pressure (P.S.I.) |
Min. Recom.'d Bend Radius |
Approx. Weight Per Ft. (lbs.) |
12WTLCT |
3/4" |
1.25" |
500 |
29.9" |
2000 |
3 1/4" |
0.92 |
16WTLCT |
1" |
1.50" |
450 |
29.9" |
1800 |
4 3/4" |
1.12 |
24WTLCT |
1 1/2" |
2.00" |
300 |
29.9" |
1200 |
9" |
1.79 |
32WTLCT |
2" |
2.65" |
250 |
29.9" |
1000 |
11 1/2" |
2.24 |
Minimum Overall Length (OAL) of Hose Assemblies with Anti-Kink Casing
3/4" and 1" sizes -- 36" OAL
1-1/2" size -- 36" OAL*
2" size -- 48" OAL*
3" and 4" sizes -- consult factory
*With some size sanitary clamped ends shorter lengths are possible.
Burst Pressure ratings at ambient 70ºF (21ºC). See applicable notes below on vacuum/pressure ratings at temperatures other than ambient.
Working Pressure is given @ 70ºF; Decrease working pressure 1% for every 2ºF above 350ºF.
Vacuum Rating is given @ 70ºF; Decrease vacuum rating 1% for every 2ºF above 212ºF.
|