Tygon®
High Purity Tubing |
|

Clear and
flexible, TYGON® 2275 High Purity Tubing
is
ideally suited for use in many sensitive
cell
culture and fermentation applications.
|
Biopharmaceutical Formulation 2275
With
an extremely low sorption rate, and
no
plasticizer to alter fluids, Tygon®
High
Purity Tubing maintains the
integrity of
sensitive solutions.
Features/Benefits
-
Provides an uncompromising fluid path
for sensitive solutions
-
Low sorption maintains fluid integrity
-
Plasticizer-free -- virtually no
extractables
-
Environmentally friendly -- safe to
dispose of through incineration
-
Documented biocompatibility to the ISO
10993 standard
-
Meets USP Class VI, FDA, and NSF
criteria
-
Highly resistant to aggressive cleaners
and sanitizers
Typical Applications
-
Sterile Filling and Dispensing Systems
-
Diagnostic Equipment
-
Nuclear Equipment
-
Laboratory Analytical Instrumentation
-
Infusion Sets for Parenterals and Drugs
-
Cosmetic Production
-
Food and Beverage Processing
-
Cell and Tissue Culture Transport
|
|
Low
Absorption/Adsorption
Maintaining fluid
integrity during transfer is critical in numerous
pharmaceutical and biotechnology applications. Loss
of fluid through migration into the tubing walls can
cause inconsistencies in final product results.
Tygon® 2275 High Purity Tubing is hydrophobic and
will resist the absorption/adsorption of aqueous
fluids. This reduction in absorption/adsorption
minimizes the risk of fluid alteration in single or
repeat use applications.
Designed for Purity
Until now, clear,
flexible tubing was restricted from use in many
applications due to concern of plasticizer
extraction. Tygon® 2275 High Purity Tubing is
entirely free of any plasticizers. This unique
tubing uses the latest in polymer technology to
provide an entirely clear and flexible tubing choice
for sensitive fluid transfer applications.
Smooth Inner Surface
Improves Sanitation
Analysis has shown
the inner surface of Tygon® 2275 High Purity Tubing
to be smoother than other frequently specified
flexible tubings. This smooth surface inhibits
particulate entrapment onto the tubing wall and
reduces the potential for bacterial growth and
contamination. A smoother fluid path also improves
fluid flow characteristics by reducing surface area
and lowering adherence of fluid onto the tubing
wall.
Reduced Disposal Concern
Tygon® 2275 High
Purity Tubing is also unique when it comes to
disposal. In today’s environment, incineration is
commonly used to dispose of contaminated materials.
Many tubings actually contribute to this problem by
releasing hazardous byproducts, such as chlorine,
when burned. Tygon® 2275 tubing only releases carbon
dioxide and water when properly incinerated.
Superb Chemical
Resistance
Tygon® 2275 High
Purity Tubing is virtually unaffected by chemical
sanitizers and cleaners. As a result, it can be
cleaned repeatedly without decreasing its service
life. The non-wettable surface of the product
facilitates complete drainage of fluid during the
cleaning process.
Click
for complete size chart
Click for Relative Chemical Resistance Properties &
Absorption
Click for Sterilization Information
|
|
Tygon®
2275 Tubing Typical Physical Properties |
|
Property |
ASTM Method |
Value or Rating |
|
Durometer Hardness - Shore A, 15 sec |
D2240-97 |
72 |
|
Color |
- |
Clear |
|
Tensile Strength - psi (MPa) |
D412-97 |
2,000 (13.8) |
|
Ultimate Elongation, % |
D412-97 |
700 |
|
Tear Resistance - lb-f/inch (kN/m) |
D1004-93 |
220 (39) |
|
Specific Gravity |
D792-91 |
0.9 |
|
Water Absorption, % - 24 hours @ 23ºC |
D570-95 |
< 0.01 |
|
Compression Set Constant Deflection, % - @
158ºF (70ºC) for 22 hours |
D395-89 - Method B |
84 |
|
Brittleness by Impact Temp - ºF (ºC) |
D746-95 |
-108 (-78) |
|
Max Recommended Operating Temp - ºF (ºC) |
- |
125 (52) |
|
Low Temperature Flexibility, ºF (ºC) |
D380-87 |
-94 (-70) |
|
Dielectric Strength - v/mil (kV/mm) |
D149-93 |
587 (23.1) |
|
Tensile Modulus, @ 200% Elongation, psi (MPa) |
D412-97 |
350 (2.4) |
|
Tensile Set, % |
D412-97 |
187 |
|
|
Unless
otherwise noted, all tests were conducted at room
temperature (73ºF). Values shown were determined
on 0.075" thick extruded strip or 0.075" thick
molded ASTM plaques or molded ASTM durometer
buttons. |
|
|
|
|
|
|
|
|
|