Javascript Menu by Deluxe-Menu.com
  Toll Free: 1-800-665-9502 / Raleigh: 919-468-7228 / Greensboro: 336-854-7840 / Roanoke: 540-774-7229

Site Map

Contact STI

Home

STI - The Premier Distributor of Fluid Handling Components, Specialized in Brand Name Flexible Tubing and Hose.

 

STI - The Premier Distributor of Fluid
Handling Components, Specializing in Brand
Name Flexible Tubing and Hose.

 

STI is ISO 9001:2000 Certified

 

 

 Request A Quote

 

 PRODUCTS
About STI  STI Facility Request A Quote Manufacturers News Site Map Home Page
 
 

AFlex Hose's Bioflex Hose Liners

   
Virgin PTFE Liner  
The Virgin PTFE Liner is Bioflex's General Purpose grade hose for use in all applications where fluids or gases are being conveyed which do not generate a risk of static charge development. Purpose  - Bioflex GP is the 'General Purpose' grade, for use in all applications where fluids or gases are being conveyed which do not generate a risk of static charge development (see 'AS')


Design 
- Bioflex GP is a virgin PTFE liner, manufactured from hose grade PTFE that conforms to the requirements of USP Class VI and FDA 21 CFR 177.1550 protocols.

EC - Electrical Continuity (between end fittings)  When EC grade is requested, it is necessary that the hose assembly supplied is electrically continuous, or conductive, between metal end fittings at each end of the hose.

The requirements for this are specified in the German Document BRG132, and the Specification EN ISO 12115, tested to EN ISO 8031 Clause 3.7, which requires that for hose assemblies with a resistance between fittings of 102 ohms, a letter "M" can be applied, or 106 ohms, a letter "Ω" can be applied. 

Braided Bioflex Hose Assemblies all meet the requirements of both "M" and "Ω".

The only exception is for assemblies without braid.  Grade AS,TO (Antistatic, Tube Only) meets the requirements of "Ω", 106 ohms, but Grade GP,TO (Natural Tube Only) does not meet either "M" or "Ω"

 

Antistatic PTFE Liner
The Antistatic PTFE Liner is an essential requirement in applications where there is the risk of an electrostatic charge build-up on the inside surface of the PTFE tube which may then discharge through the tube wall. Purpose - Bioflex AS is an essential requirement in applications where there is the risk of an electrostatic charge build-up on the inside surface of the PTFE tube which may then discharge through the tube wall.  Media passing through which create such a risk are fluids, which have a Conductance of less than 10-7 S/m (Siemens per Meter), such as fuels, solvents, freons, non-polar organics and ultra pure (WFI) water which are being transferred at a medium to high flow velocity.

All twin or multi phase media and any non-mixing media, such as powder in air, or water droplets in steam, in gases or in oil, also colloidal fluids constitute a particular hazard for static charge generation, and always require grade AS.

If in any doubt, please contact Aflex Hose.

Design  - Bioflex AS is an anti-static PTFE liner manufactured from FDA approved PTFE, and less than 2.5% of "high purity" Carbon Black material to FDA requirement 21 CFR 178.3297.  The carbon is encapsulated by the PTFE, and in normal, non-abrasive applications will not come loose to contaminate any fluid passing through - this is achieved by creating a highly polished inside surface using techniques which are unique to Bioflex Hose.

Specifications  - When "AS" (Antistatic) grade is specified, then the hose supplied will be in accordance with the requirements of BS5958 Part 2, 1991 Clause 19.3, when tested in accordance with EN ISO 8031 Clause 3.1, which requires that the resistance between a plug inserted 25mm into the bore at the end of the hose assembly, and one of the metallic end fittings should be less than 108 ohms.

NOTE  When in service, at least one end fitting must be connected to earth, to permit dissipation of the static charge from the end fitting.

 

 
 
 
 
   Copyright © 2000-2008 - STI Flow - Raleigh | Greensboro | Roanoke - North Carolina and Virginia - Toll Free: 1-800-665-9502 | Raleigh: 919-468-7228 | Greensboro: 336-854-7840 | Roanoke: 540-774-7229