Bio-Pharm Fittings from VNE - BioConnect© |
 |
BioConnect©
- Optimized recess contour
(patent approved)
- Highest press-on power
at the transitions to wetted areas prevents dirt and
germs getting into the sealing space (see ASME-BPE, Ch.
SD-3.7.2 and 3.7.6)
- Defined expansion
pockets excludes dangerous "escalator effect" between
wetted area and elastomer seat (see ASME-BPE, Ch.
SD-3.7.2)
- Self-draining even after
expansion of seal due to high temperature (see ASME-BPE,
Ch. SD-3.7.7)
- Metal-to-metal-stop
avoids stress or overcompression of gaskets (O-ring)
(see ASME-BPE, Ch. SD-3.7.8)
- nominal pressure PN16
(D6 - DN100, 1/2" - 4")
|
|
|
| |
|
|
Connect S© -
a unique solution without elastomer gasket
- Optimal recess contour
and design of the sealing metallic surface (patent
approved)
- Excellent cleanability
- Tested by
Fraunhofer-Institut for Grenzflächen-und
Bioverfahrenstechnik
- Hermetic tightness even
under repeated temperature changes
- Defined pre-stressing on
the metallic sealing surface
- No gasket - no elevator
effect
- Protection of the
sealing contour against damage
- Axial positioning by
metal-to-metal-stop
- Exact positioning by
central guidance
- Material grad 1.4435/316
L; other grades on request
- Wetted areas with
roughness Ra<0,8µm (Ra<0,5µm on demand)
- Dimensions acc. ASME-BPE,
DIN11866, DIN 11850, ISO 1127
- Material Test Report
according EN 10204-3.1 (on request ADW 2)
- Approval for pressure
application: issued by TÜV Germany
(Süddeutschland)
a) Nominal Pressure: PN 16 (DN 6 until DN 50)
PN 10 (DN 65 until DN 100) PN 100 (DN 6 until DN 40, high pressure-aseptic
connection)
|
 |
 |
 |
|
|
BioControl©
BioControl© is a
fully aseptic modular system with TÜV-approval for pressure
application.
BioControl© provides the user with a fully
hygienic port for connection control instruments, gauges,
sight glasses etc., allowing cleaning and sterilizing in
place.
BioControl© system is supported by the following
manufacturers of instruments and special equipment:
|
|
|
 |
- Endress + Hauser
- WIKA
- LABOM
- Fisher Rosemount
(EMERSON)
- Papenmeier
- Others
BioControl© allows 100% Cleaning-In-Place
where typical instrument tees stay with uncleaned dead
pockets.
|
|
|
|
|